Calgary South East Monitoring Station
4697 – 110 Ave SE | Lat. 50° 57′ 19.5444” N, Long. 113° 58′ 10.0704” W, UTM: 291454N 5649067, Elevation: 1030 m
Analytical Systems
| Parameter | Make/Model | Sampling Height (m) | Operating Range |
|---|---|---|---|
| Hydrogen Sulphide | Thermo Environmental Instruments model 45C | 4 | 0 – 100 ppb |
| Sulphur Dioxide | Thermo Environmental Instruments model 43i | 4 | 0 – 500 ppb |
| Ozone | Thermo Environmental Instruments model 49i | 4 | 0 – 500 ppb |
| Oxides of Nitrogen | Thermo Environmental Instruments model 42i | 4 | 0 – 500 ppb |
| Methane/Non-Methane and Total Hydrocarbons | Thermo Environmental Instruments model 55C | 4 | 0 – 50 ppm |
| Carbon Monoxide | Thermo Environmental Instruments model 48i | 4 | 0 – 50 ppm |
| Particulate Matter <2.5um | Thermo Environmental Instruments Sharp 5030 | 5 | 0 – 1000 ug/m3 |
| Meteorological Systems | |||
| Wind Speed | Met One Instruments model 50.5 | 10 | 0 – 120 kph |
| Wind Direction | Met One Instruments model 50.5 | 10 | 0 – 360 deg |
| External Temperature | N/A | 5 | -50 - +50 Degrees C |
| Relative Humidity | N/A | 5 | 0 – 100 % |
| Support Systems | |||
| Data Acquisition System | Environmental Systems Corporation model 8816 | N/A | N/A |
| Zero Air Supply | AENV | N/A | N/A |